B3 Yellow Zone — Hard Numbers for Layout Lock-In

For: Gemini cross-session reference  |  Date: 2026-03-04   SUPERSEDED by v03

⚠ SUPERSEDED: This v01 file contains WRONG geometry (north wall 614.8 cm, area 29.13 m², room narrows going north). The correct values are in v03: north wall 860 cm, area 34.42 m², room WIDENS going north. Column positions also corrected in v03.

Zone Dimensions (All in Meters)

Shape: RIGHT TRAPEZOID (not rectangle)

        NW (1.22, 4.31) ─────────────── NE (7.37, 4.31)
       /                  6.15 m              |
      / 4.48 m                                | 4.31 m
     /  (diagonal)                            |
    /                                         |
SW (0, 0) ──────────────────────────── SE (7.37, 0)
                 7.37 m

Origin = SW corner of south wall
X = east (→)   Y = north (↑)

Core Measurements

WhatValue (m)Value (cm)
South wall (E-W)7.37737
North wall (E-W)~6.15614.8
East wall (N-S)4.31431
NW diagonal4.48448
Diagonal horiz. component1.22122.2
Ceiling to slab3.50350
Effective height (after build)3.15315
Gross area29.13 m²
Effective volume~91.8 m³

Width at Every Level (for layout planning)

Y from south (m)Width E-W (m)Notes
0.007.37South wall
0.507.23
1.007.09
1.117.06Column row
1.506.95
2.006.81
2.506.66
3.006.52
3.506.38
4.006.23
4.316.15North wall

Formula: Width = 7.37 - (Y / 4.31) × 1.22


Columns (2 structural, cannot move)

ColumnWidth E-W (cm)Depth N-S (cm)West face X (m)East face X (m)South face Y (m)North face Y (m)
COL-160503.654.251.111.61
COL-2~5550~6.82~7.371.111.61

Daikin VRF Indoor Units (from HVAC DXF)

Unit Inside/Near Zone

UnitPosition in ZoneX (m from SW)Y (m from S)Confidence
U380Near SE corner~6.88~0.50APPROXIMATE

Units Outside Zone (adjacent areas)

UnitWhereDistance from Zone
U370/U371 (paired)East of zone (B302 area?)~2.7 m east of east wall
U328Far east (different B3 section)~10+ m east

Air Devices (Diffusers)

#Inside Zone?Position
1YES (barely)~1.73m E, near south wall
2-6NO0.9 to 4.6m WEST of zone

What This Means for Layout

  1. Only 1 VRF indoor unit (U380) appears to serve the yellow zone directly
  2. U380 is near the SE corner — close to the editing/entry area (good: non-critical zone)
  3. Most air devices are OUTSIDE the zone to the west — existing diffuser layout doesn't serve the yellow zone interior well
  4. This confirms we must redesign the “last mile” — new duct drops, new plenum boxes, new diffuser positions inside the rooms
  5. U380's position near editing/corridor aligns with Obai's plan: indoor unit sits OUTSIDE critical rooms, only ductwork penetrates

Wall Types (for construction planning)

WallTypeWhat to Do
NorthConcrete exteriorKEEP — build isolation wall inside with air gap
NW diagonalConcrete exteriorKEEP — build isolation wall inside with air gap
East10cm gypsum → Server Room B313DEMOLISH old, build STC 58-68 wall (server noise: 55-65 dBA)
SouthInterior partitionDEMOLISH, rebuild as acoustic partition

Quick Reference for Gemini

LENGTH (E-W at south): 7.37 m
LENGTH (E-W at north): 6.15 m
WIDTH (N-S):           4.31 m
DIAGONAL (NW):         4.48 m
AREA:                  29.13 m2
CEILING:               3.50 m to slab
VOLUME:                101.9 m3 raw

COL-1: center (3.95, 1.36), size 60x50cm
COL-2: center (~7.10, 1.36), size ~55x50cm

VRF U380: approximately (6.88, 0.50) — near SE corner
VRF U370/U371: outside zone, ~2.7m east

Width formula: W = 7.37 - (Y/4.31) * 1.22

Source: DXF analysis of SD-HVAC-ALL-241225-V02 + B3 Final Furniture layout 03.03.2026
Coordinate mapping approximate — HVAC contractor overlay needed for precision