B3 Yellow Zone — Hard Numbers for Layout Lock-In

For: Gemini cross-session reference | Date: 2026-03-04 | Version: v02 CORRECTED SUPERSEDED

v02: North wall corrected to 860 cm (was 614.8). Room WIDENS going north.

ZONE DIMENSIONS (ALL IN METERS) — LOCKED SSOT

Shape: RIGHT TRAPEZOID (not rectangle)
Room WIDENS going north — diagonal extends outward (west)

NW (-1.23, 4.31) ──────────────────────── NE (7.37, 4.31)
  \                    8.60 m                    |
   \ 4.48 m                                     | 4.31 m
    \  (diagonal)                                |
     \                                           |
SW (0, 0) ──────────────────────────── SE (7.37, 0)
                  7.37 m

Origin = SW corner of south wall
X = east (→)   Y = north (↑)
NW corner extends 1.23m WEST of origin

Core Measurements

WhatValue (m)Value (cm)
South wall (E-W)7.37737
North wall (E-W)8.60860
East wall (N-S)4.31431
NW diagonal4.48448
Diagonal horiz. component1.23123
Ceiling to slab3.50350
Effective height (after build)3.15315
Gross area34.42 m²
Raw volume120.5 m³
Effective volume~108.4 m³

Width at Every Level (for layout planning)

Y from south (m)Width E-W (m)Notes
0.007.37South wall
0.507.51
1.007.66
1.117.69Column row
1.507.80
2.007.94
2.508.08
3.008.23
3.508.37
4.008.51
4.318.60North wall

Formula: Width = 7.37 + (Y / 4.31) × 1.23


COLUMNS (2 structural, cannot move)

ColumnWidth E-W (cm)Depth N-S (cm)West face X (m)East face X (m)South face Y (m)North face Y (m)
COL-160503.654.251.111.61
COL-2~5550~6.82~7.371.111.61

DAIKIN VRF INDOOR UNITS (from HVAC DXF)

Unit Inside/Near Zone

UnitPosition in ZoneX (m from SW)Y (m from S)Confidence
U380Near SE corner~6.88~0.50APPROXIMATE

Units Outside Zone (adjacent areas)

UnitWhereDistance from Zone
U370/U371 (paired)East of zone (B302 area?)~2.7 m east of east wall
U328Far east (different B3 section)~10+ m east

Air Devices (Diffusers)

#Inside Zone?Position
1YES (barely)~1.73m E, near south wall
2-6NO0.9 to 4.6m WEST of zone

WHAT THIS MEANS FOR LAYOUT

  1. Only 1 VRF indoor unit (U380) appears to serve the yellow zone directly
  2. U380 is near the SE corner — close to the editing/entry area (good: non-critical zone)
  3. Most air devices are OUTSIDE the zone to the west — existing diffuser layout doesn't serve the yellow zone interior well
  4. This confirms we must redesign the "last mile" — new duct drops, new plenum boxes, new diffuser positions inside the rooms
  5. U380's position near editing/corridor aligns with Obai's plan: indoor unit sits OUTSIDE critical rooms, only ductwork penetrates
  6. Room is LARGER than initially calculated — 34.42 m² gives more usable space for 5 zones

WALL TYPES (for construction planning)

WallTypeWhat to Do
NorthConcrete exteriorKEEP — build isolation wall inside with air gap
NW diagonalConcrete exteriorKEEP — build isolation wall inside with air gap
East10cm gypsum → Server Room B313DEMOLISH old, build STC 58-68 wall (server noise: 55-65 dBA)
SouthInterior partitionDEMOLISH, rebuild as acoustic partition

QUICK REFERENCE FOR GEMINI

LENGTH (E-W at south): 7.37 m
LENGTH (E-W at north): 8.60 m  ← CORRECTED (was 6.15)
WIDTH (N-S):           4.31 m
DIAGONAL (NW):         4.48 m
AREA:                  34.42 m²  ← CORRECTED (was 29.13)
CEILING:               3.50 m to slab
VOLUME (raw):          120.5 m³  ← CORRECTED (was 101.9)
VOLUME (effective):    108.4 m³  ← CORRECTED (was 91.8)

COL-1: center (3.95, 1.36), size 60x50cm
COL-2: center (~7.10, 1.36), size ~55x50cm

VRF U380: approximately (6.88, 0.50) — near SE corner
VRF U370/U371: outside zone, ~2.7m east

Width formula: W = 7.37 + (Y/4.31) * 1.23  ← CORRECTED (+ not -)
Room WIDENS going north (opposite of v01)

Source: MediaVerse.pdf (AUTHORITATIVE) + DXF analysis
v02 corrects north wall from 614.8cm to 860cm per dimensioned PDF drawing