← Back to Project Index

B3 Yellow Zone — Hard Numbers for Layout Lock-In

For: Gemini / Grok / Claude cross-session reference | Date: 2026-03-04 | Version: v03 PNG-VERIFIED

v03: Column positions SHIFTED +39cm east. Correct positions: COL-WEST center (3.64, 1.36), COL-EAST center (7.57, 1.33), partially embedded in east wall (~50cm past, ~10cm visible).

v02: North wall corrected to 860 cm (was 614.8). Room WIDENS going north.


ZONE DIMENSIONS (ALL IN METERS) — LOCKED SSOT

Shape: RIGHT TRAPEZOID (not rectangle)
Room WIDENS going north — diagonal extends outward (west)

NW (-1.23, 4.31) ──────────────────────── NE (7.37, 4.31)
  \                    8.60 m                    |
   \ 4.48 m                                     | 4.31 m
    \  (diagonal)                                |
     \                                           |
SW (0, 0) ──────────────────────────── SE (7.37, 0)
                  7.37 m

Origin = SW corner of south wall
X = east (+)   Y = north (+)
NW corner extends 1.23m WEST of origin

Core Measurements

WhatValue (m)Value (cm)
South wall (E-W)7.37737
North wall (E-W)8.60860
East wall (N-S)4.31431
NW diagonal4.48448
Diagonal horiz. component1.23123
Ceiling to slab3.50350
Effective height (after build)3.15315
Gross area34.42 m²
Raw volume120.5 m³
Effective volume~108.4 m³

Width at Every Level (for layout planning)

Y from south (m)Width E-W (m)Notes
0.007.37South wall
0.507.51
1.007.66
1.067.67COL-EAST south face
1.117.69COL-WEST south face
1.367.76Column row center
1.507.80
1.617.83Both columns north face
2.007.94
2.508.08
3.008.23
3.508.37
4.008.51
4.318.60North wall

Formula: Width = 7.37 + (Y / 4.31) × 1.23


COLUMNS (2 structural, cannot move) — PNG-VERIFIED

COL-WEST (Interior Column — Labeled 60x50 in Reference PNG)

PropertyValueNotes
Size (E-W x N-S)60 x 50 cmPNG reference dimensions
Center (zone coords)(3.64, 1.36) m= (364, 136) cm from SW
West face X3.34 m (334 cm)from SW
East face X3.94 m (394 cm)from SW
South face Y1.11 m (111 cm)from south wall
North face Y1.61 m (161 cm)from south wall

COL-EAST (Partially Embedded in East Wall)

PropertyValueNotes
Size (E-W x N-S)60 x 55 cm5 cm deeper than COL-WEST
Center (zone coords)(7.57, 1.33) m= (757, 133) cm from SW
West face X7.27 m (727 cm)from SW
East face X7.87 m (787 cm)50 cm past east wall (737), ~10 cm visible
South face Y1.06 m (106 cm)5 cm further south than COL-WEST
North face Y1.61 m (161 cm)ALIGNED with COL-WEST

Column Span Summary

SpanDistanceNotes
COL-WEST east face to COL-EAST west face333 cmClear span between columns
COL-EAST east face to east wall50 cm pastPartially embedded (~10 cm visible inside room)
Column north faces to north wall270 cmBoth columns aligned
Center-to-center393 cmBetween column centers

DAIKIN VRF INDOOR UNITS (from HVAC DXF)

Unit Inside/Near Zone

UnitPosition in ZoneX (m from SW)Y (m from S)Confidence
U380Near SE corner~6.88~0.50APPROXIMATE

Units Outside Zone (adjacent areas)

UnitWhereDistance from Zone
U370/U371 (paired)East of zone (B302 area?)~2.7 m east of east wall
U328Far east (different B3 section)~10+ m east

Air Devices (Diffusers)

#Inside Zone?Position
1YES (barely)~1.73m E, near south wall
2-6NO0.9 to 4.6m WEST of zone

WALL TYPES (for construction planning)

WallTypeWhat to Do
NorthConcrete exterior (30cm thick)KEEP — build isolation wall inside with air gap
NW diagonalConcrete exteriorKEEP — build isolation wall inside with air gap
East10cm gypsum to Server Room B313DEMOLISH old, build STC 58-68 wall (server noise: 55-65 dBA)
SouthInterior partitionDEMOLISH, rebuild as acoustic partition

DXF COORDINATE MAPPING

For cross-referencing with AutoCAD:

Zone origin (SW) = DXF (-67.326, -144.217) meters
Transform: zone_x_cm = (dxf_x + 67.326) x 100
           zone_y_cm = (dxf_y + 144.217) x 100

Key DXF reference points:
  North wall inner face: y = -139.911 m (30cm concrete)
  East wall partition:   x = -59.956 m (gypsum to B313)
  South wall:            y = -144.217 m

QUICK REFERENCE BLOCK

LENGTH (E-W at south): 7.37 m
LENGTH (E-W at north): 8.60 m
WIDTH (N-S):           4.31 m
DIAGONAL (NW):         4.48 m
AREA:                  34.42 m2
CEILING:               3.50 m to slab
VOLUME (raw):          120.5 m3
VOLUME (effective):    108.4 m3

COL-WEST: center (3.64, 1.36)m, size 60x50cm  ← SHIFTED +39cm east
COL-EAST: center (7.57, 1.33)m, size 60x55cm  ← SHIFTED +39cm east
COL gap: 333cm clear span
COL-EAST: 50cm past east wall, ~10cm visible inside room

VRF U380: approximately (6.88, 0.50) — near SE corner
VRF U370/U371: outside zone, ~2.7m east

Width formula: W = 7.37 + (Y/4.31) * 1.23
Room WIDENS going north

Source: 2026-03-04_Final-Layouts-04-03-2026.dxf (AUTHORITATIVE DXF)
Cross-ref: 2026-03-04_MediaVerse-Reference.png (Obai's dimensioned plan)
v03 corrects column positions from DXF extraction (was PDF-derived in v02)