← Back to Project Index
B3 Yellow Zone — Hard Numbers for Layout Lock-In
For: Gemini / Grok / Claude cross-session reference | Date: 2026-03-04 | Version: v03 PNG-VERIFIED
v03: Column positions SHIFTED +39cm east. Correct positions: COL-WEST center (3.64, 1.36), COL-EAST center (7.57, 1.33), partially embedded in east wall (~50cm past, ~10cm visible).
v02: North wall corrected to 860 cm (was 614.8). Room WIDENS going north.
ZONE DIMENSIONS (ALL IN METERS) — LOCKED SSOT
Shape: RIGHT TRAPEZOID (not rectangle)
Room WIDENS going north — diagonal extends outward (west)
NW (-1.23, 4.31) ──────────────────────── NE (7.37, 4.31)
\ 8.60 m |
\ 4.48 m | 4.31 m
\ (diagonal) |
\ |
SW (0, 0) ──────────────────────────── SE (7.37, 0)
7.37 m
Origin = SW corner of south wall
X = east (+) Y = north (+)
NW corner extends 1.23m WEST of origin
Core Measurements
| What | Value (m) | Value (cm) |
| South wall (E-W) | 7.37 | 737 |
| North wall (E-W) | 8.60 | 860 |
| East wall (N-S) | 4.31 | 431 |
| NW diagonal | 4.48 | 448 |
| Diagonal horiz. component | 1.23 | 123 |
| Ceiling to slab | 3.50 | 350 |
| Effective height (after build) | 3.15 | 315 |
| Gross area | 34.42 m² | — |
| Raw volume | 120.5 m³ | — |
| Effective volume | ~108.4 m³ | — |
Width at Every Level (for layout planning)
| Y from south (m) | Width E-W (m) | Notes |
| 0.00 | 7.37 | South wall |
| 0.50 | 7.51 | — |
| 1.00 | 7.66 | — |
| 1.06 | 7.67 | COL-EAST south face |
| 1.11 | 7.69 | COL-WEST south face |
| 1.36 | 7.76 | Column row center |
| 1.50 | 7.80 | — |
| 1.61 | 7.83 | Both columns north face |
| 2.00 | 7.94 | — |
| 2.50 | 8.08 | — |
| 3.00 | 8.23 | — |
| 3.50 | 8.37 | — |
| 4.00 | 8.51 | — |
| 4.31 | 8.60 | North wall |
Formula: Width = 7.37 + (Y / 4.31) × 1.23
COLUMNS (2 structural, cannot move) — PNG-VERIFIED
COL-WEST (Interior Column — Labeled 60x50 in Reference PNG)
| Property | Value | Notes |
| Size (E-W x N-S) | 60 x 50 cm | PNG reference dimensions |
| Center (zone coords) | (3.64, 1.36) m | = (364, 136) cm from SW |
| West face X | 3.34 m (334 cm) | from SW |
| East face X | 3.94 m (394 cm) | from SW |
| South face Y | 1.11 m (111 cm) | from south wall |
| North face Y | 1.61 m (161 cm) | from south wall |
COL-EAST (Partially Embedded in East Wall)
| Property | Value | Notes |
| Size (E-W x N-S) | 60 x 55 cm | 5 cm deeper than COL-WEST |
| Center (zone coords) | (7.57, 1.33) m | = (757, 133) cm from SW |
| West face X | 7.27 m (727 cm) | from SW |
| East face X | 7.87 m (787 cm) | 50 cm past east wall (737), ~10 cm visible |
| South face Y | 1.06 m (106 cm) | 5 cm further south than COL-WEST |
| North face Y | 1.61 m (161 cm) | ALIGNED with COL-WEST |
Column Span Summary
| Span | Distance | Notes |
| COL-WEST east face to COL-EAST west face | 333 cm | Clear span between columns |
| COL-EAST east face to east wall | 50 cm past | Partially embedded (~10 cm visible inside room) |
| Column north faces to north wall | 270 cm | Both columns aligned |
| Center-to-center | 393 cm | Between column centers |
- Both columns: north faces aligned at Y=1.61m
- COL-EAST extends 5 cm further south than COL-WEST (55cm vs 50cm depth)
- Build around without rigid coupling (isolate with neoprene/air gap)
DAIKIN VRF INDOOR UNITS (from HVAC DXF)
Unit Inside/Near Zone
| Unit | Position in Zone | X (m from SW) | Y (m from S) | Confidence |
| U380 | Near SE corner | ~6.88 | ~0.50 | APPROXIMATE |
Units Outside Zone (adjacent areas)
| Unit | Where | Distance from Zone |
| U370/U371 (paired) | East of zone (B302 area?) | ~2.7 m east of east wall |
| U328 | Far east (different B3 section) | ~10+ m east |
Air Devices (Diffusers)
| # | Inside Zone? | Position |
| 1 | YES (barely) | ~1.73m E, near south wall |
| 2-6 | NO | 0.9 to 4.6m WEST of zone |
WALL TYPES (for construction planning)
| Wall | Type | What to Do |
| North | Concrete exterior (30cm thick) | KEEP — build isolation wall inside with air gap |
| NW diagonal | Concrete exterior | KEEP — build isolation wall inside with air gap |
| East | 10cm gypsum to Server Room B313 | DEMOLISH old, build STC 58-68 wall (server noise: 55-65 dBA) |
| South | Interior partition | DEMOLISH, rebuild as acoustic partition |
- B313 gap: 10 cm between B3 east wall and server room
DXF COORDINATE MAPPING
For cross-referencing with AutoCAD:
Zone origin (SW) = DXF (-67.326, -144.217) meters
Transform: zone_x_cm = (dxf_x + 67.326) x 100
zone_y_cm = (dxf_y + 144.217) x 100
Key DXF reference points:
North wall inner face: y = -139.911 m (30cm concrete)
East wall partition: x = -59.956 m (gypsum to B313)
South wall: y = -144.217 m
QUICK REFERENCE BLOCK
LENGTH (E-W at south): 7.37 m
LENGTH (E-W at north): 8.60 m
WIDTH (N-S): 4.31 m
DIAGONAL (NW): 4.48 m
AREA: 34.42 m2
CEILING: 3.50 m to slab
VOLUME (raw): 120.5 m3
VOLUME (effective): 108.4 m3
COL-WEST: center (3.64, 1.36)m, size 60x50cm ← SHIFTED +39cm east
COL-EAST: center (7.57, 1.33)m, size 60x55cm ← SHIFTED +39cm east
COL gap: 333cm clear span
COL-EAST: 50cm past east wall, ~10cm visible inside room
VRF U380: approximately (6.88, 0.50) — near SE corner
VRF U370/U371: outside zone, ~2.7m east
Width formula: W = 7.37 + (Y/4.31) * 1.23
Room WIDENS going north
Source: 2026-03-04_Final-Layouts-04-03-2026.dxf (AUTHORITATIVE DXF)
Cross-ref: 2026-03-04_MediaVerse-Reference.png (Obai's dimensioned plan)