STATUS: LOCKED (2026-03-04)
THIS FILE IS THE SINGLE SOURCE OF TRUTH (SSOT) FOR ALL GEOMETRY.
DO NOT MODIFY. DO NOT DEVIATE. ALL CALCULATIONS MUST USE THESE VALUES.
Source:
Source/2026-03-04_Final-Layouts-04-03-2026.dxf(Authoritative DXF, 2026-03-04)Cross-ref:
Source/2026-03-04_MediaVerse-Reference.png(Obai's dimensioned plan)Extraction:
Source/2026-03-04_DXF-Extraction-Report.md(Full DXF analysis)
| Wall | Length (cm) | Length (m) | Notes |
|---|---|---|---|
| South wall | 737 | 7.37 | Entry side, interior partition |
| North wall | 860 | 8.60 | Concrete exterior — WIDER than south |
| East wall | 431 | 4.31 | Perpendicular height, gypsum to B313 |
| NW diagonal | 448 | 4.48 | Concrete exterior facade |
Cross-referenced with Source/2026-03-04_MediaVerse-Reference.png — North at top, matching architectural convention
| Point | X (cm) | Y (cm) | X (m) | Y (m) | Description |
|---|---|---|---|---|---|
| SW | 0 | 0 | 0.00 | 0.00 | South wall, west end (diagonal base) |
| SE | 737 | 0 | 7.37 | 0.00 | South wall, east end |
| NE | 737 | 431 | 7.37 | 4.31 | North wall, east end |
| NW | -123 | 431 | -1.23 | 4.31 | North wall, west end (1.23m WEST of SW) |
| Parameter | Value | Formula |
|---|---|---|
| Gross area | 34.42 m² | ½ × (737 + 860) × 431 = 344,153.5 cm² |
| Ceiling to slab | 3.50 m (350 cm) | Gypsum T-bar at 2.90m is removable |
| Raw volume | 120.5 m³ | 34.42 × 3.50 |
| Float floor deduction | -15 cm | Neoprene pads + plywood |
| Ceiling plenum deduction | -60 cm | T-grid + insulation + ducts + services (see SSOT) |
| Acoustic ceiling height | 2.75 m (275 cm) | 350 - 15 - 60 |
| Effective volume | 94.66 m³ | 34.42 × 2.75 |
W(Y) = 7.37 + (Y / 4.31) × 1.23 meters
(Y = distance from south wall in meters, room WIDENS going north)
| Y from south (m) | Width E-W (m) | Notes |
|---|---|---|
| 0.00 | 7.37 | South wall (narrowest) |
| 0.50 | 7.51 | |
| 1.00 | 7.66 | |
| 1.11 | 7.69 | Column row |
| 1.50 | 7.80 | |
| 2.00 | 7.94 | |
| 2.50 | 8.08 | |
| 3.00 | 8.23 | |
| 3.50 | 8.37 | |
| 4.00 | 8.51 | |
| 4.31 | 8.60 | North wall (widest) |
| Column | Size (cm) | Center (m) | Zone Faces (cm from SW) | Notes |
|---|---|---|---|---|
| COL-WEST | 60 × 50 | (3.64, 1.36) | W:334 E:394 S:111 N:161 | In-zone structural column |
| COL-EAST | 60 × 55 | (7.57, 1.33) | W:727 E:787 S:106 N:161 | Mostly embedded in east wall (~10 cm visible inside, ~50 cm past wall) |
| Parameter | Value |
|---|---|
| HVAC system | Daikin VRF (Variable Refrigerant Flow) |
| Indoor unit | U380 near SE corner |
| Zone count | 5: VO Live, Control, Video/Podcast, Editing, Sound Lock + Buffer Spine |
| NC-15 target | VO Live Room (box-in-box) |
| NC-25 target | Control Room, Video/Podcast Studio |
| NC-30-35 target | Editing workstations |
| Buffer spine | REQUIRED |
| Server room (B313) | East wall, 55-65 dB(A), 10 cm gap |
| Point | DXF X (m) | DXF Y (m) | Transform |
|---|---|---|---|
| SW | -67.326 | -144.217 | zone_x = (dxf_x + 67.326) × 100 cm |
| SE | -59.956 | -144.217 | zone_y = (dxf_y + 144.217) × 100 cm |
| NE | -59.956 | -139.911 | |
| NW | -68.556 | -139.911 |
Source/2026-03-04_Final-Layouts-04-03-2026.dxf (DEFINITIVE SOURCE)Source/2026-03-04_DXF-Extraction-Report.mdSource/2026-03-04_MediaVerse-Reference.pngCalculations/2026-03-04_v03_Area-Calculation.mdScope/2026-03-04_v03_Locked-Scope.htmlHVAC/2026-03-04_v03_Zone-Numbers-For-Gemini.mdHVAC/2026-03-04_v03_B3-Zone-Map-HVAC.html