← Back to Project Index

TechTown Acoustics 2.0 — DXF Extraction Report

Source: 2026-03-04_Final-Layouts-04-03-2026.dxf
Date: 2026-03-04  |  Author: Claude (Opus 4.6)


DXF File Metadata

PropertyValue
FileTechtown Syria Office Building - Final layouts 04.03.2026.dxf
Size48.3 MB (5,662,863 lines)
DXF VersionAC1032 (AutoCAD 2018+)
$INSUNITS1 (drawing units)
Dimension Scaledimlfac=100.0 (coordinates in meters, dimensions display in cm)
Total Entities25,967 in modelspace
Total Layers64

Entity Type Distribution (Top 10)

TypeCount
LINE19,835
LWPOLYLINE1,681
INSERT1,477
SPLINE898
ARC760
DIMENSION492
MTEXT337
HATCH235
CIRCLE128
POINT79

Key Layers for B3 Zone

LayerPurpose
1 - Existing WallConcrete exterior walls (polylines)
COLUMNS & STRUCTUREStructural columns
0 - Dimentions and AnnotationsDimension entities
3 - Glass Partiton-DoorsGlass partitions
0General/miscellaneous lines
3fold commentsDesign notes/dimensions

B3 Zone Location in DXF

The B3 zone is located in the NW corner of the basement level. The building is oriented with coordinates in meters, with the building extending across negative x and y quadrants.

B3 Zone Bounding Area (DXF coordinates)

Reference Points


Zone Geometry (VERIFIED)

Vertex Coordinates

PointDXF X (m)DXF Y (m)Zone X (cm)Zone Y (cm)Zone X (m)Zone Y (m)Description
SW-67.326-144.2170.00.00.000.00South wall, west end (diagonal base)
SE-59.956-144.217737.00.07.370.00South wall, east end
NE-59.956-139.911737.0430.67.374.31North wall, east end
NW-68.556-139.911-123.0430.6-1.234.31North wall, west end

Coordinate system: Zone coordinates use origin at SW corner, X positive east, Y positive north.

Transform: zone_x = (dxf_x + 67.326) × 100 cm; zone_y = (dxf_y + 144.217) × 100 cm

Wall Measurements

WallLength (cm)Length (m)DXF VerificationNotes
South wall737.07.37SE_x - SW_x = 7.370 mEntry side, interior partition
North wall860.08.60NE_x - NW_x = 8.600 mConcrete exterior, 30cm thick
East wall430.64.31DIMENSION entity: 430.6 cmGypsum partition to B313
NW diagonal447.84.48sqrt(123² + 430.6²) = 447.8 cmConcrete exterior facade

Diagonal Verification

Shape: Right Trapezoid


Area & Volume

ParameterValueFormula/Source
Gross area34.38 m²½ × (737 + 860) × 430.6 / 10000
Ceiling to slab3.50 m (350 cm)From scope (gypsum T-bar at 2.90m is removable)
Raw volume120.3 m³34.38 × 3.50
Float floor deduction-15 cmNeoprene pads + plywood
Acoustic ceiling deduction-20 cmSuspended acoustic panels
Effective height3.15 m (315 cm)350 - 15 - 20
Effective volume108.3 m³34.38 × 3.15

Note: Using exact east wall = 430.6 cm (from DXF) rather than rounded 431 cm gives area = 34.38 m² vs previous 34.42 m². The difference is 0.04 m² (negligible). For consistency with locked reference, 34.42 m² (using rounded 431 cm) remains the SSOT value.


Width Formula

W(Y) = 7.37 + (Y / 4.31) × 1.23 meters

(Y = distance from south wall in meters, room WIDENS going north)

Y from south (m)Width E-W (m)Width (cm)Notes
0.007.37737.0South wall (narrowest)
0.507.51751.3
1.007.66765.5
1.117.69768.7COL-WEST south face
1.367.76775.8Column row center
1.507.80779.8
2.007.94794.1
2.508.08808.4
3.008.23822.6
3.508.37836.9
4.008.51851.2
4.318.60860.0North wall (widest)

Column Positions (FROM DXF — WRONG X POSITIONS)

CRITICAL CORRECTION: The DXF polylines identified below have correct Y coordinates, correct widths (60cm), correct depths (50/55cm), correct col-to-col gap (333cm), and correct gap to north wall (270cm) — but their X positions are shifted 71 cm west of the actual positions. The PNG reference dimensions (334 + 60 + 333 = 727) are authoritative for column X positions. The DXF extraction identified the wrong polylines on the COLUMNS & STRUCTURE layer.

CORRECT positions (PNG-derived, now in SSOT-GEOMETRY.md): The DXF-extracted values below are preserved for documentation but DO NOT USE for any calculations.

COL-WEST (Interior Column — Labeled 60×50 in PNG) — X values wrong, shifted 71cm west

PropertyDXF ValueZone ValueNotes
Size60 × 50 cmwidth × depthConfirmed from polyline bounds
DXF bounds X[-65.0863, -64.4863]
DXF bounds Y[-143.1113, -142.6113]
Center (zone)(254.0, 135.6) cm= (2.54, 1.36) m
West face224.0 cmfrom SW
East face284.0 cmfrom SW
South face110.6 cm≈ 111 cm from south wall ✓
North face160.6 cmfrom south wall
Gap to north wall270.0 cm✓ matches PNG

COL-EAST (Partially Embedded in East Wall) — X values wrong, shifted 71cm west

PropertyDXF ValueZone ValueNotes
Size60 × 55 cmwidth × depth5 cm deeper than COL-WEST
DXF bounds X[-61.1563, -60.5563]
DXF bounds Y[-143.1613, -142.6113]
Center (zone)(647.0, 133.1) cm= (6.47, 1.33) m
West face617.0 cmfrom SW
East face677.0 cmfrom SW
South face105.6 cm≈ 106 cm (5 cm further south than COL-WEST)
North face160.6 cmALIGNED with COL-WEST north face
Gap to north wall270.0 cm✓ matches PNG
East face to east wall60.0 cmPartially extends into east side

Column Alignment Notes

Structural Spans at Column Row

SpanDistance (cm)Notes
Diagonal wall → COL-WEST west face262.7At y=1.36m from south
COL-WEST width60.0
COL-WEST east → COL-EAST west333.0✓ matches PNG "333"
COL-EAST width60.0
COL-EAST east → East wall60.0Partially showing into east side
Total room width at column row775.7W(1.36) = 7.757 m ✓
Center-to-center393.0Between column centers

PNG "334" Reference Note

The PNG reference shows 334 + 60 + 333 = 727 as the structural span. The 333 and 60 are DXF-confirmed. The 334 measurement reference point could not be precisely identified in the DXF geometry — at the column row center (y=1.36m), the diagonal wall to COL-WEST west face measures 262.7 cm. The 334 may reference a structural grid line or a measurement convention not directly derivable from B3 zone geometry alone. The key verified spans remain 333 cm (col-to-col) and 60 cm (column width).


North Wall Properties

PropertyValueSource
Outer face Y-139.6113 mWall polyline P5/P6
Inner face Y-139.9113 mWall polyline P11/P12
Wall thickness30.0 cmConcrete
Full building span35.87 mP11 to P12 (entire building width)
B3 portion8.60 mNE to NW (860 cm)

Dimension Entities in B3 Area (Unique, from DXF)

Value (cm)DescriptionLayer
955.9NW exterior wall diagonal segment0 - Dimentions and Annotations
430.6East wall height0 - Dimentions and Annotations
395.6Building segment (outside B3)0 - Dimentions and Annotations
392.2Building segment0 - Dimentions and Annotations
357.1Wall segment0
330.7Wall segment0 - Dimentions and Annotations
300.0Perpendicular measurement0
295.0Perpendicular to diagonal0 - Dimentions and Annotations
274.0Perpendicular measurement0 - Dimentions and Annotations
254.5Horizontal span0
233.3Horizontal span at column area0 - Dimentions and Annotations
123.7≈ NW diagonal horizontal component0 - Dimentions and Annotations

Key Project Parameters (from Scope)

ParameterValue
HVAC systemDaikin VRF (Variable Refrigerant Flow)
Indoor unitU380 near SE corner
Zone count5: VO Live, Control, Video/Podcast, Editing, Sound Lock + Buffer Spine
NC-15 targetVO Live Room (box-in-box)
NC-25 targetControl Room, Video/Podcast Studio
NC-30-35 targetEditing workstations
Buffer spineREQUIRED
Server room (B313)East wall, 55-65 dB(A), 10 cm gap
B313 gap to east wall10 cm (from PNG reference)

Cross-Reference: DXF vs PNG vs SSOT

MeasurementPNGDXF DerivedSSOT (current)Status
South wall737737.0737✅ Match
North wall860860.0860✅ Match
East wall431430.6431✅ Match (±0.4cm rounding)
NW diagonal448447.8448✅ Match (±0.2cm rounding)
Area34.3834.42✅ Match (rounding diff)
Col-to-col gap333333.0333✅ Match
Column width6060.060✅ Match
Col gap to north270270.0270✅ Match
COL-WEST from south111110.6111✅ Match (±0.4cm)
COL-WEST depth5050.050✅ Match
COL-EAST depth55.0~55✅ Match
COL-EAST to east wall60.0✅ New (partially showing)
COL-WEST center X2.54 m3.64 mDXF WRONG (shifted 71cm west) — PNG is authoritative, then SHIFTED +39cm east
COL-WEST center Y1.36 m1.36 m✅ Match
COL-EAST center X6.47 m7.57 mDXF WRONG (shifted 71cm west) — PNG is authoritative, then SHIFTED +39cm east
COL-EAST center Y1.33 m1.33 m✅ Match
Left span (diagonal→COL-W west)334262.7373❌ DXF gives 262.7 — confirms DXF polylines are wrong entities (SSOT updated: +39cm east shift)

Files Referenced

FileLocationStatus
DXF sourceSource/2026-03-04_Final-Layouts-04-03-2026.dxf✅ In project
PNG referenceSource/2026-03-04_MediaVerse-Reference.png✅ In project
This reportSource/2026-03-04_DXF-Extraction-Report.md✅ Created

Report generated: 2026-03-04  |  Source DXF: Final Layouts 04.03.2026  |  Status: COMPLETE (Column X positions corrected — DXF polylines identified were wrong entities, shifted 71cm west. PNG reference is authoritative for column X.)